Alat Pencatat Data Konduktivitas/Salinitas Air Asin HOBO Salt Water Conductivity/Salinity Data Logger U24-002-C

Alat Pencatat Data Konduktivitas/Salinitas Air Asin HOBO Salt Water Conductivity/Salinity Data Logger U24-002-C Pencatat data hemat biaya untuk mengukur salinitas, konduktivitas, dan suhu di lingkungan air asin dengan perubahan salinitas yang relatif kecil (±5.000 μS/cm) seperti teluk air asin, atau untuk mendeteksi kejadian salinitas seperti arus naik, hujan badai, dan pelepasan muatan. Data dari pencatat ini dapat digunakan dengan data dari Pencatat Oksigen Terlarut HOBO U26 untuk memantau persentase saturasi oksigen terlarut.

Description

Features
  • ​Non-contact sensor provides long life
  • Easy access to sensor for cleaning and shedding air bubbles
  • Two user-selectable ranges provide measurements from 100 to 55,000 uS/cm.
  • Delrin housing will not corrode in saltwater
  • HOBOware Pro software enables start/end-point calibration to compensate for any fouling and provides easy conversion to specific conductance and salinity using the Practical Salinity Scale 1978 (PSS-78)
  • USB optical interface provides high-speed, reliable salinity data offload in wet environments
  • Compatible with the HOBO Waterproof Shuttle for easy and reliable data retrieval and transport
  • Non-contact sensor with titanium pentoxide coating keeps the sensor from coming in contact with the water, thereby preventing tarnishing or corrosion associated with traditional electrode sensors; sensor coating is inert, so fouling can be wiped off easily

 

Specifications
Measurements:
Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale 1978)
Conductivity Measurement Ranges:
Low range: 100 to 10,000 uS/cm
High range: 5000 to 55,000 uS/cm
Conductivity Calibrated Range – Temperature Range:
5° to 35°C
41° to 95°F
Conductivity Extended Ranges:
Low range: 100 to 10,000 uS/cm
High range: 5000 to 55,000 uS/cm
(readings below these ranges reported as 0)
Temperature Measurement Range:
-2° to 36°C
28° to 97°F
Specific Conductance Accuracy (in Calibrated Range using Conductivity Assistant and Calibration Measurements):
Low range: 3% of reading or 50 µS/cm, whichever is greater
High range: 5% of reading, in waters within a range of ±3,000 µS/cm; waters with greater variation can have substantially greater error
Conductivity Resolution: 2 uS/cm (typical)
Temperature Accuracy: 0.1°C (0.2°F) at 25°C (77°F)
Temperature Resolution:
0.01°C
0.02°F
Conductivity drift:
Up to 12% sensor drift per month, exclusive of drift from fouling. Monthly start- and end-point calibration should be used with the HOBOware Conductivity Assistant to achieve the specified Specific Conductance accuracy.
Response time: 1 second to 90% of change (in water)
Operating range: -2° to 36°C (28° to 97°F) – non-freezing
Memory:
18,500 temperature and conductivity measurements when using one conductivity range; 11,500 sets of measurements when using both conductivity ranges (64 KB total memory)
Sample rate: 1 second to 18 hrs, fixed or multiple-rate sampling with up to 8 user-defined sampling intervals
Clock accuracy: +/- 1 minute per month
Battery life: 3 years (@ 1 min logging)
Maximum depth:
70 m
225′
Weight: 193 gm (6.82 ounces), buoyancy in freshwater: -59.8 gm (-2.11 ounces)
Size: 3.18 cm diameter x 16.5 cm, with 6.3 mm mounting hole (1.25″ diameter x 6.5″, ¼” hole)
Wetted housing materials:
Delrin®, epoxy, stainless steel retaining ring, polypropylene, Buna rubber O-ring, titanium pentoxide (inert coating over sensor) – all materials are suitable for long-term use in saltwater.
Environmental Rating;  IP68
What’s in the box
  • HOBO U24-002-C Conductivity Data Logger
  • Communications window protective cap

Contact Us:
– Telp & Whatsapp 0812-1248-2471
– Email alfin@testindo.com

Reviews

There are no reviews yet.

Be the first to review “Alat Pencatat Data Konduktivitas/Salinitas Air Asin HOBO Salt Water Conductivity/Salinity Data Logger U24-002-C”

Your email address will not be published. Required fields are marked *