Description
Features
- Non-contact sensor provides long life
- Easy access to sensor for cleaning and shedding air bubbles
- Two user-selectable ranges provide measurements from 100 to 55,000 uS/cm.
- Delrin housing will not corrode in saltwater
- HOBOware Pro software enables start/end-point calibration to compensate for any fouling and provides easy conversion to specific conductance and salinity using the Practical Salinity Scale 1978 (PSS-78)
- USB optical interface provides high-speed, reliable salinity data offload in wet environments
- Compatible with the HOBO Waterproof Shuttle for easy and reliable data retrieval and transport
- Non-contact sensor with titanium pentoxide coating keeps the sensor from coming in contact with the water, thereby preventing tarnishing or corrosion associated with traditional electrode sensors; sensor coating is inert, so fouling can be wiped off easily
Specifications
Measurements:
-
Actual Conductivity, Temperature, Specific Conductance at 25C (calculated), Salinity (calculated using PSS-78, the Practical Salinity Scale 1978)
Conductivity Measurement Ranges:
-
Low range: 100 to 10,000 uS/cmHigh range: 5000 to 55,000 uS/cm
Conductivity Calibrated Range – Temperature Range:
-
5° to 35°C41° to 95°F
Conductivity Extended Ranges:
-
Low range: 100 to 10,000 uS/cmHigh range: 5000 to 55,000 uS/cm(readings below these ranges reported as 0)
Temperature Measurement Range:
-
-2° to 36°C28° to 97°F
Specific Conductance Accuracy (in Calibrated Range using Conductivity Assistant and Calibration Measurements):
-
Low range: 3% of reading or 50 µS/cm, whichever is greaterHigh range: 5% of reading, in waters within a range of ±3,000 µS/cm; waters with greater variation can have substantially greater error
Conductivity Resolution: 2 uS/cm (typical)
Temperature Accuracy: 0.1°C (0.2°F) at 25°C (77°F)
Temperature Resolution:
-
0.01°C0.02°F
Conductivity drift:
-
Up to 12% sensor drift per month, exclusive of drift from fouling. Monthly start- and end-point calibration should be used with the HOBOware Conductivity Assistant to achieve the specified Specific Conductance accuracy.
Response time: 1 second to 90% of change (in water)
Operating range: -2° to 36°C (28° to 97°F) – non-freezing
Memory:
-
18,500 temperature and conductivity measurements when using one conductivity range; 11,500 sets of measurements when using both conductivity ranges (64 KB total memory)
Sample rate: 1 second to 18 hrs, fixed or multiple-rate sampling with up to 8 user-defined sampling intervals
Clock accuracy: +/- 1 minute per month
Battery life: 3 years (@ 1 min logging)
Maximum depth:
-
70 m225′
Weight: 193 gm (6.82 ounces), buoyancy in freshwater: -59.8 gm (-2.11 ounces)
Size: 3.18 cm diameter x 16.5 cm, with 6.3 mm mounting hole (1.25″ diameter x 6.5″, ¼” hole)
Wetted housing materials:
-
Delrin®, epoxy, stainless steel retaining ring, polypropylene, Buna rubber O-ring, titanium pentoxide (inert coating over sensor) – all materials are suitable for long-term use in saltwater.
Environmental Rating; IP68
What’s in the box
- HOBO U24-002-C Conductivity Data Logger
- Communications window protective cap
Contact Us:
– Telp & Whatsapp 0812-1248-2471
– Email alfin@testindo.com
Reviews
There are no reviews yet.