Description
| Column temperature Box | |||
| Furnace Size | 28×30×18cm | ||
| Temperature control Range | Above room temperature5℃~450℃;Using liquid nitrogen cold traps:-80℃~400℃;Using dry ice traps:-55℃~400℃ | ||
| Temperature setting accuracy | 0.1℃ | ||
| Maximum program heating rate | 120℃/min | ||
| Maximum once method run time | 999.99min | ||
| Program temperature maximum order | 7 stages | ||
| Program heating rate | 0.1~120℃/min(Incremental 0.1℃) | ||
| Operation Column loss compensation (dual channel) | |||
| Heating Zone | |||
| 6 independent control Heating zone control (excluding furnace temperature, two inlet, two detectors, two auxiliary heating area auxiliary heating zone maximum operating temperature ) | |||
| 300℃ | |||
| Detectors | |||
| Hydrogen Flame Ionization detector FID | |||
| Maximum operating temperature | 450℃ | ||
| Minimum detectable limit | ≤2.5pgC/s [n-C16] | ||
| Dynamic linear range | ≥107(±10%) | ||
| Data acquisition frequency | The highest: 100Hz | ||
| Thermal conductivity cell detector TCD | |||
| Maximum operating temperature | 400℃ | ||
| Minimum detectable limit | <400pg C3H8/ml(He) | ||
| Dynamic linear range | 105(±5%) | ||
| data acquisition frequency | The highest: 100Hz | ||
| Flame photometric detector FPD | |||
| Maximum operating temperature | 250℃ | ||
| Minimum detectable limit | <4pgC/sec,<1pg P/sec | ||
| Selective | 105gS/gC,106gP/gC | ||
| Dynamic linear Range | >103S,>104P | ||
| Electronic Capture Detector ECD | |||
| Maximum operating temperature | 400℃ | ||
| Detector compensation Gas Type | 5% Methane/Argon or nitrogen | ||
| Minimum detectable limit | <0.01Ppg/s lindane | ||
| Dynamic linear range | >5×1055 | ||
| data acquisition frequency | 最高100Hz | ||
| Radioactive sources | <12mCi 63Ni | ||
| Nitrogen and phosphorus detectors NPD | |||
| Maximum operating temperature | 450℃ | ||
| Minimum check out limit | <0.2 pg N/sec,<0.2 pg P/sec | ||
| Dynamic linear Range | 105N,105P | ||
| Minimum detection limit | <0.3pg C/Sec | ||
| The above detectors are suitable for filling column and capillary column | |||
| Optional configuration | |||
| Anti-control software | Automatic Feed b6891n | ||
Parameter tabel adalah untuk parameter Model Standar perusahaan, kami mendukung parameter kustomisasi pelanggan
Industri aplikasi
1. Analisis gas terlarut dalam minyak transformator;
2. Analisis etilen oksida dalam perangkat medis.
3. Analisis gas oven kokas;
4. Analisis residu pestisida;
Analisis alkohol dalam darah; 5.
6. Analisis gas alam dan gas cair;
7. Analisis TVOC lingkungan dalam ruangan;
8. Analisis komponen minuman keras;
9. Analisis gas dengan kemurnian tinggi;
10. Deteksi residu pelarut dari bahan kemasan.