Kromatografi Gas Pengambilan Sampel Otomatis (Automatic Sampling Gas Chromatograph)

Kromatografi gas pengambilan sampel otomatis digunakan untuk analisis kuantitatif dan kualitatif untuk menentukan konstanta fisika dan kimia seperti koefisien distribusi, koefisien aktivitas, berat molekul, dan luas permukaan sampel dalam fasa diam. Instrumen untuk menganalisis komponen gas campuran.

Description

Column temperature Box
Furnace Size 28×30×18cm
Temperature control Range Above room temperature5℃~450℃;Using liquid nitrogen cold   traps:-80℃~400℃;Using dry ice traps:-55℃~400℃
Temperature setting accuracy 0.1℃
Maximum program heating rate 120℃/min
Maximum once method run time 999.99min
Program temperature maximum order 7 stages
Program heating rate 0.1~120℃/min(Incremental 0.1℃)
Operation Column loss compensation (dual   channel)
Heating Zone
6 independent control Heating zone control   (excluding furnace temperature, two inlet, two detectors, two auxiliary   heating area auxiliary heating zone maximum operating temperature )
300℃
Detectors
Hydrogen Flame Ionization detector FID
Maximum operating temperature 450℃
Minimum detectable limit ≤2.5pgC/s [n-C16]
Dynamic linear range ≥107(±10%)
Data acquisition frequency The highest: 100Hz
Thermal conductivity cell detector  TCD
Maximum operating temperature 400℃
Minimum detectable limit <400pg C3H8/ml(He)
Dynamic linear range 105(±5%)
data acquisition frequency The highest: 100Hz
Flame photometric detector  FPD
Maximum operating temperature 250℃
Minimum detectable limit <4pgC/sec,<1pg P/sec
Selective 105gS/gC,106gP/gC
Dynamic linear Range >103S,>104P
Electronic Capture Detector ECD
Maximum operating temperature 400℃
Detector compensation Gas Type 5% Methane/Argon or nitrogen
Minimum detectable limit <0.01Ppg/s lindane
Dynamic linear range >5×1055
data acquisition frequency 最高100Hz
Radioactive sources <12mCi  63Ni
Nitrogen and phosphorus detectors NPD
Maximum operating temperature 450℃
Minimum check out limit <0.2 pg N/sec,<0.2 pg P/sec
Dynamic linear Range 105N,105P
Minimum detection limit <0.3pg C/Sec
The above detectors are suitable for   filling column and capillary column
Optional configuration
Anti-control software Automatic Feed b6891n

Parameter tabel adalah untuk parameter Model Standar perusahaan, kami mendukung parameter kustomisasi pelanggan

Industri aplikasi

1. Analisis gas terlarut dalam minyak transformator;

2. Analisis etilen oksida dalam perangkat medis.

3. Analisis gas oven kokas;

4. Analisis residu pestisida;

Analisis alkohol dalam darah; 5.

6. Analisis gas alam dan gas cair;

7. Analisis TVOC lingkungan dalam ruangan;

8. Analisis komponen minuman keras;

9. Analisis gas dengan kemurnian tinggi;

10. Deteksi residu pelarut dari bahan kemasan.

 