Description
Inspeksi laser yang aman yang mengutamakan efisiensi dalam deteksi keberadaan

Deteksi jendela kotor, menilai jarak deteksi tidak dapat mencapai yang telah ditetapkan, secara otomatis memutus output, keselamatan terpandu.
Ideal untuk menghindari rintangan dan navigasi pada robot bergerak

Deteksi akurat pada area kecil dan luas.
Implementasi pengaturan regional yang mudah

Area yang dilindungi dan dijaga dapat dengan mudah diatur, sehingga dapat dipasang di posisi mana pun. Seri SC-C memiliki area penjagaan maksimum 3 m meskipun ukurannya kecil.
Products Lineup
| Appearance | Type | Detection radius | Output type | Model |
![]() |
Obstacle avoidance type | 2 m (1.8 % reflectance) | PNP | SC-S02P |
![]() |
3 m (1.8 % reflectance) | PNP | SC-S03P |
Technical Specifications
PNP output
| Model | SC-S02P | SC-S03P | |
| Type | Obstacle avoidance type | ||
| Detection light source | Wavelength 905 nm, Class I laser products | ||
| Scanning angle range | 270 | ||
| Angular resolution | 0.5 | ||
| Measuring accuracy | Standard, ±4 cm@1sigma | ||
| Ambient temperature | Work | -10 to +55 °C (no frost and condensation) | |
| Storage | -40 to +70 °C | ||
| Ambient humidity | Work | 35 to 85 % RH | |
| Storage | 35 to 95 % RH | ||
| Light interference resistance | 15000 lux | ||
| Vibration resistant | Frequency 10 to 55 Hz; Amplitude: 0.35±0.05 mm; Scanning times: three axes, 20 times per axis | ||
| Shock resistant | Acceleration 10 g; pulse duration: 16 ms; number of collisions: three axes, 1000±10 per axis | ||
| Protection class | IP65 | ||
| Dimensions | 80×80×95 mm | ||
| Power voltage | DC 9 V to DC 30 V | ||
| Power consumption | 5 W (no load on outputs) | ||
| Configurable functions | Defense zone configuration | Users can configure the defense zone of SC-S series to the desired shape through the configuration software | |
| Response time | 80 ms (2-turn scanning) to 640 ms (16-turn scanning), default 80 ms | ||
| Reset function | Configurable for auto or manual reset, default auto reset | ||
| External device | Monitor the status of the normally closed contacts of the load when an external relay or contactor load is connected, and the EDM function is disabled by default. | ||
| Area group switching | 4 groups of external input signals (Z1, Z2, Z3, Z4) to realize the switching of 16 area groups, default Z1, Z2, Z3, Z4 is not connected when the area group 1 work. | ||
| Mounting bracket (sold separately) | Horizontal/vertical/vibration damping/shield mounting optional | ||
Kontak Kami :
Telp/Whatsapp : 0812 1248 2471
Email : alfin@testindo.com





Reviews