Description
Penguji Permeabilitas Gas C130H didasarkan pada metode tekanan diferensial, dan secara profesional dapat diterapkan untuk penentuan laju transmisi gas, koefisien kelarutan, koefisien difusi, dan koefisien permeabilitas film plastik, film komposit, bahan penghalang tinggi, lembaran, dan foil logam pada suhu yang berbeda. Proses pengujian sesuai dengan GB, ISO, ASTM, dan standar internasional lainnya.
Product FeaturesNote1
Innovative structure design & upgraded automatic operation
- Test cells with brand new pop-up drawer type design
- Automatic specimen clamping with uniform force
- Components are supplied by global well-known manufacturers, which are reliable and stable in performance
- Intelligent test mode, one-button test operation (test temperature should be set in advance) and automatic stop
- Scientific research mode provides more flexible parameter and function settings for analysis of gas transmission rate, solubility coefficient, diffusion coefficient and permeability coefficient
Upgraded testing accuracy and efficiency
- Imported high precision vacuum sensor for tests of ultra-high barrier property (0.01 ~ 0.09 cm3/ m2·24h·0.1MPa) materials with high accuracy and repeatability
- Imported pneumatic control system with ultra-low failure rate and extremely long service life, which guarantees the seal performance of the whole system
- Imported high precision vacuum pump improves the evacuation efficiency and generates vacuum up to 0.2Pa
- The vacuum pump is turned on/off automatically
- For low and medium barrier property materials, test time is less than 4 hours (including evacuation time)
- For high barrier property materials, test time is less than 8 hours (including evacuation time)
- Three independent test cells provide individual test results, specimens can be replaced as desired
Excellent temperature and pressure control technique
- 360°circulation constant temperature technology is applied in the instrument to remain the test temperature fluctuation below 0.05°C
- Labthink’s unique pressure compensation technique is used to maintain the stable differential pressure (pressure change is less than 0.2KPa)
- The pressure of high pressure chamber can be adjusted from 10KPa to 210KPa and maintained precisely
Versatile functions based on standards, customization available
- Various types of gases are testable: sole gas, mixed gases, poisonous gases, explosive gases and other dangerous gases (customization is required)
- The humidity of test gas can be adjusted and controlled automatically by the system, without requiring human intervention (customization is required for humidifying device)
- Labthink’s unique data fitting function can provide the test results of gas transmission rate, permeability coefficient, solubility coefficient and diffusion coefficient at extreme temperatures
- Reference film for fast calibration ensures accurate and universal test data
- Calibration port for verifying test temperature and pressure
- Conform to the test standards of differential pressure method
High end, secure and easy-to-use embedded computer controlled system
- Integrated design of instrument and software minimizes the malfunctions caused by computer virus or faulty operations and ensures the performance of the instrument and data security
- The instrument can be easily operated with a mouse, a keyboard and a monitor. Windows operation interface for testing operations and displaying data
- The system is equipped with four USB ports and dual Internet ports for convenient data transmission
- The instrument meets the requirements of China GMP of pharmaceutical industry (optional)
- Labthink’s unique DataShieldTM system for data management and connecting information management system (optional)
Test Principle
C130H is designed in accordance with differential pressure method. The pre-conditioned specimen is mounted in the gas diffusion cell as to form a sealed barrier between two chambers. The lower-pressure chamber is firstly evacuated, followed by the evacuation of the entire cell. A flow of gas is thereafter introduced into the evacuated higher-pressure chamber and a constant pressure difference is generated between the two chambers. The gas permeates through the specimen from higher pressure side into the lower pressure side. The gas permeability and other barrier properties of the specimen can be obtained by monitoring the pressure changes in the lower chamber.
Test StandardNote1
ISO 2556, ISO 15105-1, GB/T 1038-2000, ASTM D1434, JIS K7126-1, YBB 00082003
ApplicationsNote1
This instrument is applicable to the determination of gas permeability of:
Basic Applications |
---|
|
|
Extended Applications |
|
|
|
|
|
|
|
|
|
Technical SpecificationsNote2
Specifications | Film Test |
---|---|
Test Range | 0.01 ~ 50,000 cm3/m2·24h·0.1MPa |
Resolution | 0.001 cm3/ m2·24h·0.1MPa |
Temperature Range | 10°C~ 50°C (room temperature 23°C) |
Resolution | 0.01°C |
Temperature Fluctuation | ±0.05°C |
Temperature Accuracy | ±0.3°C (calibration port) |
Vacuum Resolution | 0.01Pa |
Vacuum Accuracy | Displayed Value ±0.2% (1%~100% of sensor range) |
Vacuum Degree of Test Chamber | < 10 Pa |
Number of Specimens | 3 with independent test results Customization available for other number of specimens |
Specimen Size | Φ97 mm |
Test Area | 38.48 cm2 |
Test Gas | O2, N2, and CO2 (outside of supply scope) Humidifying of Test Gas (customization available) |
Test Pressure | 10KPa ~ 210KPa |
Gas Supply Pressure | 0.5 Mpa ~ 0.6 Mpa (73psi ~ 87psi ) |
Port Size | Φ6 mm PU Tubing |
Instrument Dimension | 710 mm (L) × 350 mm (W) × 630 mm (H) |
Power Supply | 220VAC±10% 50Hz / 120VAC±10% 60Hz |
Net Weight | 100 kg |
Configurations
- Standard Configurations
- Instrument, Monitor, Keyboard, Mouse, Round Sample Cutter, Vacuum Grease, Fast Quantitative Filter Paper and Vacuum Pump, Φ6 mm PU tubing (3m)
- Optional Parts
- GMP Computer System, DataShieldTM Note3, Air Compressor
- Note
- 1. The gas supply port of the instrument is Φ6 mm PU tubing;
2. Customers need to prepare gas supply.
Note 1: The described test standard, applications and product features should be in line with Technical Specifications.
Note 2: The parameters in the table are measured by professional operators in Labthink laboratory under strictly controlled laboratory conditions.